Query/Question:
Why do batch updates via RIH or the Salesforce Connector fail with Error 17007: LIFE_CYCLE_READ_TIME_OUT_ERROR on the LCAService:Reltio/DVFAction hook?
Probable Cause:
Data Validation Function (DVF) execution exceeds the lifecycle timeout limit (default 1000–5000ms) under heavy concurrent write loads, typically due to database read throttling, unindexed lookup validations, or overly broad DVF trigger criteria evaluated on every entity save.
Recommended fix:
Reduce connector batch size to alleviate concurrent read/write contention.
Optimize DVF rules in the L3 configuration by applying specific preconditions (e.g., executing validation only when target attributes are modified rather than on every
beforeSaveevent).If necessary, adjust
dvfTimeOutin tenant physical configuration in coordination with Reltio Support.
Documentation links:
[Reltio Data Validation Functions (DVF)] (
https://docs.reltio.com/en/model-data/data-validation-functions) | [Lifecycle Actions & Timeouts] (https://docs.reltio.com/en/model-data/lifecycle-actions)